Beam and block floor insulation

What U-value a beam and block floor needs, where the insulation goes, and why it pays to settle the build-up before the walls go up.

Where does the insulation go?

In most beam and block floors the insulation goes on top of the deck, not underneath it. The beams and blocks sit over a ventilated void, so the deck itself stays cold. The insulation then separates the warm room from the cold deck, and a screed or board finish goes on top. The other common route is a thermal floor, where insulated panels replace the concrete blocks between the beams.

Either way the void underneath still needs ventilating. Our ground floors guide covers the void and vent sizes, and the floor details page shows the standard sections.

What U-value does the floor need?

A U-value measures how much heat escapes through the floor. The lower the number, the better. The figures below come from Approved Document L for dwellings in England.

Situation Figure What it means
New house, limit for the floor 0.18 W/m²K The worst the floor is allowed to be. It is the same in the 2021 edition and the 2026 edition.
New floor in an extension 0.18 W/m²K The same in both editions. A lesser figure may be fine if meeting it causes real problems with adjoining floor levels.
New floor replacing an old one in an existing house 0.18 W/m²K The same in both editions, and no worse than the floor it replaces. The same allowance for adjoining floor levels applies.
New house, reference design in the 2021 edition 0.13 W/m²K The floor used in the comparison design the whole house is measured against. It is not a limit.

The last row catches people out. On a new house, a floor at the 0.18 limit may not be enough, because the house as a whole has to pass its energy calculation. Your SAP assessor will often set a tighter floor figure to make that work, so ask for it before you choose your insulation.

The 2026 edition of Approved Document L takes effect on 24 March 2027, with transitional rules for some work already under way. If your job is close to that date, ask your Building Control body which edition applies.

Replacing an old floor in an existing house

Taking out a tired suspended timber floor and putting in beam and block is a common job in older houses. For Approved Document L it matters whether you are replacing the floor or only renovating it:

  • A replacement floor: a floor built to replace an existing one should meet the same 0.18 W/m²K limit as a new floor, and be no worse than the floor it replaces. A new beam and block floor in place of an old timber one falls here.
  • A renovated floor: if you keep the floor structure and only renew the deck or the screed, the guidance is different. Where the existing floor is worse than 0.70 W/m²K, it should be improved to 0.25 W/m²K, as long as that is technically feasible and pays back within 15 years.

In both cases a lesser figure may be accepted where meeting it would cause real problems with adjoining floor levels. That comes up often when one room gets a new floor and the rooms next to it stay as they are, so work out your build-up before you order. Speak to your Building Control body before you start, because they decide what applies to your job.

The void under the new floor still needs ventilating, and the existing walls must be able to carry the beams. Our ground floors guide compares beam and block with a timber floor side by side.

Why you can’t look up one thickness

There is no single insulation thickness that gives a U-value on every beam and block floor. The result depends on:

  • The shape of the floor: ground floors are worked out using the exposed perimeter divided by the floor area. A long narrow floor has more edge for its size, so it usually needs more insulation than a compact one. A 10m by 8m floor with all four sides exposed has 36m of perimeter over 80m², a ratio of 0.45.
  • The ground and the void: the soil under the floor and the ventilated void both play a part.
  • The beam layout: on insulated panel systems the beam spacing sets how much of the floor is concrete and how much is insulation.
  • The insulation itself: different boards insulate differently, so the same thickness gives a different result.

Makers publish tables of thickness against perimeter and area ratio, and these are useful for a first idea. For Building Control you need a calculation for your actual floor.

Extensions have one helpful rule: Approved Document L says the floor U-value of an extension may be calculated using the exposed perimeter and floor area of the whole enlarged house. That can reduce the insulation needed, which helps when you have to match an existing floor level. See our extensions guide.

Know your floor build-up? Send your plans and tell us the insulation and finish you have in mind. We’ll allow for the weight in the design, with the layout drawing and calculations included. Get a quote for your floor.

The main insulation options

Option How it works Worth knowing
Rigid boards with a screed Boards on the deck, then a sand and cement or liquid screed Works well with underfloor heating. Allow for the screed to dry.
Rigid boards with a floating floor Boards on the deck, then tongue-and-groove flooring boards A dry finish with no drying time. One large maker calls for a polythene vapour barrier under the insulation with this finish.
Insulated panel floor Insulated panels in place of concrete blocks, with a structural concrete topping British Precast says these can typically reach 0.1 W/m²K or better. The topping is part of the structure, so it must be built as designed.

Each insulation maker sets its own rules for screed depth, membranes and laying. As a guide, one large maker asks for at least 65mm of sand and cement screed, or about 40mm for a calcium sulphate screed. Follow the sheet for the product you buy.

Stopping heat loss at the walls

The edge of the floor is where insulation most often goes wrong. Approved Document L asks for the junction between floor and wall to keep the insulation continuous:

  • Perimeter insulation at the floor edge should meet, or run the full depth of, the main floor insulation.
  • On masonry walls, the wall insulation should run at least one full block height (215mm) below the underside of the floor, and below the depth of the floor insulation.
  • Lightweight blocks in the inner leaf can also help to reduce heat loss at the junction.

Leaving out the perimeter strip is one of the common mistakes listed on our floor details page. It is cheap to fit and awkward to add later.

Underfloor heating

British Precast describes beam and block floors as ideal bases for underfloor heating. The pipes usually sit in the screed above the insulation, so the heat goes up into the room. Our underfloor heating guide covers the build-up, the rules and the screed in full. The 2026 edition of Approved Document L asks for a thermal resistance of at least 1.25 m²K/W under underfloor heating that sits directly above the ground or an unheated space, so tell your heating designer and your SAP assessor about the floor early. If you tell us you are using a thick screed, we can allow for the weight in the calculations.

Work out your levels before the walls go up

Insulation is the reason many floors end up at the wrong height. The beams go in early, but everything on top of them has to finish level with your door thresholds and, on an extension, with the existing floor.

So add the build-up together first. For illustration only, a 150mm beam with 100mm of insulation and a 65mm screed comes to 315mm before the floor covering. Your own figures will differ, and prestressed beams have a slight upward camber that the finishes need to allow for. Our self-build guide explains when to make these decisions.

Don’t forget the weight

A screed adds far more weight to the floor than insulation does, and that weight goes into the floor design. If you change from a board finish to a screed after the layout is done, tell us, because the beams may need to be checked again. Our page on layouts and calculations shows what goes into the design.

What we need from you

The floor design for a real job is done for that job. Send your plans, the site postcode, the U-value from your SAP assessor if you have one, and the insulation and finish you plan to use. If you haven’t chosen yet, tell us and we can talk it through. Send your plans for a free quote or call 02475 095700.

What happens after you send your plans

You do not need to have chosen your insulation before you ask for a price. The quote form asks for your name, phone number, email, and the site address and postcode. Plans help us price the floor accurately, and you can upload them as PDF, image, DWG or ZIP files, but they are not essential.

  1. You send your plans. Architect’s drawings or a sketch with the inside sizes of each room. Anything that shows the walls and spans.
  2. We set out the floor. Our engineers work out the beam depth, the spacing and any doubled beams, and produce the layout drawing and the structural calculations your Building Control officer will ask for.
  3. You get a fixed price. A clear quote for the design, beams, blocks and delivery.
  4. Delivered to site. Beams are made to length and delivered with the blocks, with crane offload where needed, ready for your builder to lay.

Send us your plans for a free quote or call 02475 095700.

Frequently asked questions

What U-value does a beam and block floor need?

Approved Document L sets a limit of 0.18 W/m²K for floors in new houses and new floors in extensions. On a new house your SAP calculation will often need a better figure than the limit, so ask your assessor.

Does the insulation go above or below the beams?

Usually above. Rigid boards go on the deck under a screed or floating floor. The other common route is insulated panels between the beams with a structural concrete topping.

How thick should the insulation be?

It depends on the shape of the floor, the ground and the insulation you choose, so no single thickness works for every floor. Makers publish tables as a first guide, and your floor needs its own U-value calculation for Building Control.

Does the floor still need ventilating if it is insulated?

Usually, yes. The void under a suspended ground floor is ventilated to keep it dry, and the insulation sits above it. Our ground floors guide gives the vent sizes.

Can I use underfloor heating on beam and block?

Yes. Beam and block makes a good base for underfloor heating, usually with pipes in a screed above the insulation. Tell us about the screed so the weight is allowed for in the design.

Will the new Part L change my floor?

The 2026 edition of Approved Document L, which takes effect on 24 March 2027, keeps the 0.18 W/m²K floor limit, but the house as a whole still has to pass its energy calculation. Your SAP assessor can tell you the floor figure your job needs.

What U-value does a replacement floor in an existing house need?

Approved Document L says a floor built to replace an existing one should meet 0.18 W/m²K and be no worse than the floor it replaces. A lesser figure may be accepted where it would cause real problems with adjoining floor levels, so check with your Building Control body.