Beam and block sizes, dimensions and weights

The typical sizes of the beams and blocks, how far apart the beams sit, how thick the floor is and what it all weighs.

A beam and block floor is made from two parts: precast concrete beams, usually 150mm or 225mm deep, and concrete blocks 440mm x 215mm x 100mm that sit between them. This guide gives the typical sizes, the spacing, the depth of the finished floor and what the parts weigh, so you can plan levels, lifting and delivery. The figures are typical ones. The sizes for your floor are set on its layout drawing.

Beam and block sizes at a glance

Part Typical size Worth knowing
Beam depth 150mm, 175mm or 225mm The depths given by British Precast, the trade body. 150mm is the usual house beam
Beam width About 125mm to 215mm at the base Varies from maker to maker
Beam length Made to length for your job The gap between the walls plus the bearing at each end
Infill block 440mm x 215mm x 100mm The standard walling block size
Beam spacing About 300mm to 615mm, centre to centre Set by which way the blocks are turned
Beam weight About 35kg per metre (150mm deep), 68kg per metre (225mm deep) Typical figures from British Precast
Don’t know which size you need? You don’t have to. Send us your plans and we’ll set out the beams, the spacing and the blocks for your floor, with the layout drawing and calculations included. Get a quote for your floor.

Beam sizes: depth, width and length

Floor beams are prestressed concrete, shaped like an upside-down T. The wide base leaves a ledge on each side, and the blocks sit on those ledges.

  • Depth: British Precast gives beam depths of 150mm, 175mm and 225mm. Most house floors use a 150mm beam. The 225mm beam is for longer spans and heavier loads.
  • Width: this is where makers differ most. In the published tables of large UK makers, a standard 150mm beam is about 125mm wide at the base, a wide 150mm beam about 215mm, and a 225mm beam about 135mm. A wider beam carries more, so it spans further.
  • Length: beams are made to length for each job. One large maker’s data sheet says its beams are made in 50mm steps. The beam is longer than the room, because each end sits on the wall: British Precast gives a nominal bearing of 100mm on masonry and 75mm on steel. So a room 4.0m wide between masonry walls needs beams about 4.2m long.
  • How far they reach: British Precast says spans of up to 8m can be achieved, depending on the load. Our span guide has a table of typical spans for each beam size and spacing.

Beams must never be cut, drilled or notched on site to change their size. If the walls have moved from the drawing, tell us before the beams are made.

Block sizes

The standard infill block is 440mm long, 215mm wide and 100mm thick. That is the same size as a common concrete walling block, which is why builders know it well. With a 150mm or 225mm beam, the top of the 100mm block finishes level with the top of the beam, giving a flat deck.

  • The standard: British Precast says infill blocks may be standard walling blocks to BS EN 771 or purpose made flooring blocks, and should be load tested to carry a central point load of 3.5kN.
  • The type matters, not only the size: light and dense blocks are the same size but weigh very different amounts, and the floor is designed for one of them. One large maker’s data sheet says the density of the blocks should not be more than the figure on the drawing. So don’t swap the blocks for a heavier type without asking.
  • Blocks at the walls: British Precast says that where infill blocks are built into a load-bearing wall, they should be at least as strong as the blocks in that wall. Cut blocks and thin slip blocks fill the gaps at the ends and edges.
  • Insulated floors: some floors use shaped insulation panels in place of concrete blocks, with a concrete topping. These are made for their own system and come in different sizes. Our insulation guide compares the options.

Beam spacing: how far apart the beams sit

The spacing, or centres, is measured from the middle of one beam to the middle of the next. It is set by the blocks. Turn the block so its 440mm length bridges the gap and the beams sit at their widest spacing. Turn it so the 215mm side bridges the gap and the beams are much closer together. Mixing wide and narrow bays gives a spacing in between.

Beam Wide spacing Mixed Close spacing
150mm deep, standard beam (about 125mm wide) About 525mm About 415mm About 300mm
150mm deep, wide beam (about 215mm wide) About 615mm About 505mm About 390mm
225mm deep beam (about 135mm wide) About 535mm About 420mm About 310mm

These are typical figures from the published tables of large UK makers. Closer spacing means more beams sharing the load, so the floor spans further or carries more. Under a wall or a heavy item, two or three beams are often placed side by side. The spacing in each part of your floor is shown on the layout drawing. See layouts and calculations for how it is worked out.

How thick is a beam and block floor?

The deck itself is as deep as the beam: 150mm, 175mm or 225mm. The blocks sit level with the top of the beam, so they do not add to it. The finished floor is thicker, because of what goes under and over the deck:

  • The void underneath: on a ground floor, the example in Approved Document C has a ventilated space at least 150mm clear from the ground to the underside of the floor. On clay that can swell, the drawing may show more.
  • The beam: 150mm, 175mm or 225mm. A 225mm beam takes 75mm more depth than a 150mm one.
  • Insulation: the thickness depends on the U-value you need and the board you choose.
  • Screed or boards: the finish on top of the insulation.

For illustration only, a 150mm beam with 100mm of insulation and a 65mm screed comes to 315mm from the underside of the beam to the top of the screed, before the floor covering. Your own build-up will differ.

Prestressed beams also have a slight upward curve, called camber. British Precast says allowance must be made for it in the finishes and the overall floor thickness, so tell your screeder. Add the whole build-up together before the walls are built to level, because the floor depth sets the wall levels.

How much do the beams weigh?

British Precast gives typical weights of 35kg per metre for a 150mm deep beam and 68kg per metre for a 225mm deep beam. Multiply by the length to get the weight of one beam:

Beam length 150mm deep beam 225mm deep beam
3m About 105kg About 205kg
4m About 140kg About 270kg
5m About 175kg About 340kg
6m About 210kg About 410kg
7m Not usual at this length About 475kg

These are typical weights, and wider beams weigh more. Most beams are far too heavy to carry safely by hand, so plan how each one gets from the lorry to its place on the walls. If you are planning the lift, ask us for the weights of the beams on your job. Our installation guide covers delivery and placing the beams.

How much does the whole floor weigh?

It depends on the beams, how close together they are, and above all on the blocks, because a dense block weighs far more than a lightweight one of the same size. So there is no single figure for the floor’s own weight. It is worked out for your floor and shown in the calculations as the dead load, together with the screed and finishes.

One figure is fixed by the guidance. For a floor between storeys in a house, Approved Document E gives concrete beams with infilling blocks as an example for sound, where the beams and blocks weigh at least 220kg per square metre. See upper floors.

How much weight can the floor carry?

A floor is designed for a stated load, not a single weight limit. House floors are normally designed for an imposed load of 1.5 kN/m², which is roughly 150kg on every square metre, spread across the floor. That allows for people and furniture. Screed, finishes and partitions are added to the design on top of it.

Anything heavier or more concentrated needs to be in the design from the start: a block wall built off the floor, a stone finish, a cast-iron bath, a large kitchen island. Garage floors carry vehicles and are designed differently. Tell us what is going on the floor and it will be allowed for in the calculations.

Which size do you need?

You don’t need to choose. The beam depth, the width, the spacing and the block type all depend on each other, and on your spans and loads. That is why every floor is designed for the job it goes into. A size table like this one helps you plan levels and lifting, but it is not a design, and Building Control will normally ask for the layout drawing and calculations for your actual floor.

What happens after you send your plans

The quote form asks for your name, phone number, email, and the site address and postcode. Plans help us price the floor accurately, and you can upload them as PDF, image, DWG or ZIP files, but they are not essential.

  1. You send your plans. Architect’s drawings or a sketch with the inside sizes of each room. Tell us about access for the lorry and anything heavy going on the floor.
  2. We set out the floor. Our engineers work out the beam depth, the spacing and any doubled beams, and produce the layout drawing and the structural calculations your Building Control officer will ask for. Every floor is designed for the job it goes into.
  3. You get a fixed price. A clear quote for the design, beams, blocks and delivery.
  4. Delivered to site. Beams are made to length and delivered with the blocks, with crane offload where needed, ready for your builder to lay.

Send us your plans for a free quote or call 02475 095700.

Frequently asked questions

What size are beam and block floor beams?

British Precast gives beam depths of 150mm, 175mm and 225mm. Widths vary by maker, from about 125mm to about 215mm at the base. Beams are made to length for each job, and the sizes for your floor are shown on its layout drawing.

What size blocks are used in a beam and block floor?

The standard infill block is 440mm x 215mm x 100mm, the same size as a common concrete walling block. The block type and density are chosen as part of the floor design, so use the blocks shown on the drawing.

How thick is a beam and block floor?

The deck is as deep as the beam, usually 150mm or 225mm, because the blocks sit level with the top of the beam. Insulation and screed go on top, and a ground floor has a ventilated void of at least 150mm underneath in the Approved Document C example.

How much does a beam and block floor beam weigh?

British Precast gives typical weights of 35kg per metre for a 150mm deep beam and 68kg per metre for a 225mm deep beam. So a 4m long 150mm beam weighs about 140kg, and a 6m long 225mm beam about 410kg.

How far apart are the beams in a beam and block floor?

Typically between about 300mm and 615mm from centre to centre. The spacing depends on which way the 440mm x 215mm blocks are turned and on the width of the beam. Closer spacing lets the floor span further or carry more.

What weight can a beam and block floor take?

House floors are normally designed for an imposed load of 1.5 kN/m², roughly 150kg on every square metre, spread across the floor. Heavier items such as block walls, stone finishes or vehicles have to be allowed for in the design, so tell us about them at the start.

Ready to get your floor priced?

Get a free quote →